*** EDIT: As of FreeBSD 8.0, many LSI cards use the mpt driver, for which there is now an mptutil to monitor and manage RAID arrays.  I will have an associated Nagios plugin very soon!
 
*** EDIT: As of FreeBSD 8.0, many LSI cards use the mpt driver, for which there is now an mptutil to monitor and manage RAID arrays.  I will have an associated Nagios plugin very soon!
  
Line 9: Line 17:
 
== Linux Compat ==
 
== Linux Compat ==
 
To get megacli installed, we need to enable linux binary compatibility.  In addition, we need to enable Fedora Core 6, which is in dev.  To do this, please do the following:
 
To get megacli installed, we need to enable linux binary compatibility.  In addition, we need to enable Fedora Core 6, which is in dev.  To do this, please do the following:
<ol><li>Add 'compat.linux.osrelease=2.6.12' to /etc/sysctl.conf</li>
+
&lt;ol>&lt;li>Add 'compat.linux.osrelease=2.6.12' to /etc/sysctl.conf&lt;/li>
<li>Install /usr/ports/emulators/linux_base-fc6</li>
+
&lt;li>Install /usr/ports/emulators/linux_base-fc6&lt;/li>
<li>Add the following two lines to /etc/fstab:
+
&lt;li>Add the following two lines to /etc/fstab:
<pre>linproc /compat/linux/proc linprocfs rw 0 0
+
&lt;pre>linproc /compat/linux/proc linprocfs rw 0 0
linsysfs /compat/linux/sys linsysfs rw 0 0</pre></li>
+
linsysfs /compat/linux/sys linsysfs rw 0 0&lt;/pre>&lt;/li>
</ol>
+
&lt;/ol>
  
 
== megacli ==
 
== megacli ==
<ol><li>In our setup, the only RAID adapter we had showed up as host1, rather than host0, in the linux proc device.  To fix this, we need to edit some system source.  Edit /usr/src/sys/compat/linsysfs/linsysfs.c, and change line 180:
+
&lt;ol>&lt;li>In our setup, the only RAID adapter we had showed up as host1, rather than host0, in the linux proc device.  To fix this, we need to edit some system source.  Edit /usr/src/sys/compat/linsysfs/linsysfs.c, and change line 180:
<br /><br />
+
&lt;br />&lt;br />
 
Original:
 
Original:
<pre>if (dinfo->cfg.baseclass == PCIC_STORAGE) {</pre>
+
&lt;pre>if (dinfo->cfg.baseclass == PCIC_STORAGE) {&lt;/pre>
 
New:
 
New:
<pre>if (dinfo->cfg.baseclass == PCIC_STORAGE && dinfo->cfg.subclass == PCIS_STORAGE_RAID) {</pre>
+
&lt;pre>if (dinfo->cfg.baseclass == PCIC_STORAGE &amp;&amp; dinfo->cfg.subclass == PCIS_STORAGE_RAID) {&lt;/pre>
</li>
+
&lt;/li>
<li>Now, cd /usr/src and make buildkernel && make installkernel.  Don't reboot quite yet.</li>
+
&lt;li>Now, cd /usr/src and make buildkernel &amp;&amp; make installkernel.  Don't reboot quite yet.&lt;/li>
  
<li>As of 11/5/2008, the FreeBSD port for linux-megacli was listed as broken due to an unfetchable file.  I don't know the backstory to this, but I've found the file and you can download it [[Media:1.01.40_Linux_Cli.zip|here]].  Place this file in /usr/ports/distfiles.</li>
+
&lt;li>As of 11/5/2008, the FreeBSD port for linux-megacli was listed as broken due to an unfetchable file.  I don't know the backstory to this, but I've found the file and you can download it [[Media:1.01.40_Linux_Cli.zip|here]].  Place this file in /usr/ports/distfiles.&lt;/li>
  
<li>Install the /usr/ports/sysutils/linux-megacli port.  Feel free to ignore the install notes that come up, as they're all covered here.</li>
+
&lt;li>Install the /usr/ports/sysutils/linux-megacli port.  Feel free to ignore the install notes that come up, as they're all covered here.&lt;/li>
<li>Add the following line to /boot/loader.conf:
+
&lt;li>Add the following line to /boot/loader.conf:
<pre>mfi_linux_load="YES"</pre></li>
+
&lt;pre>mfi_linux_load="YES"&lt;/pre>&lt;/li>
<li>Reboot.</li>
+
&lt;li>Reboot.&lt;/li>
</ol>
+
&lt;/ol>
  
 
== Testing ==
 
== Testing ==
 
After you've rebooted your system, you should be able to run the following command and get output describing your disk layout:
 
After you've rebooted your system, you should be able to run the following command and get output describing your disk layout:
<pre># megacli -LDInfo -LALL -aALL</pre>
+
&lt;pre># megacli -LDInfo -LALL -aALL&lt;/pre>
  
 
Here's our output from the above command with a 12 disk RAID 50:
 
Here's our output from the above command with a 12 disk RAID 50:
<pre>Adapter 0 -- Virtual Drive Information:
+
&lt;pre>Adapter 0 -- Virtual Drive Information:
 
Virtual Disk: 0 (Target Id: 0)
 
Virtual Disk: 0 (Target Id: 0)
 
Name:
 
Name:
Line 51: Line 59:
 
Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU
 
Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU
 
Access Policy: Read/Write
 
Access Policy: Read/Write
Disk Cache Policy: Disk's Default</pre>
+
Disk Cache Policy: Disk's Default&lt;/pre>
  
 
== Nagios Monitoring ==
 
== Nagios Monitoring ==
 
The following script, coupled with Nagios and NRPE will allow you to monitor the status of your MegaRAID adapter:
 
The following script, coupled with Nagios and NRPE will allow you to monitor the status of your MegaRAID adapter:
<pre>#!/usr/bin/perl -w
+
&lt;pre>#!/usr/bin/perl -w
 
use strict;
 
use strict;
 
use warnings;
 
use warnings;
Line 114: Line 122:
 
} else {
 
} else {
 
exit $ERRORS{'OK'};
 
exit $ERRORS{'OK'};
}</pre>
+
}&lt;/pre>

Revision as of 17:37, 23 November 2010



Under Construction! Please Visit Reserve Page. Page Will Be Available Shortly


CLICK HERE


      • EDIT: As of FreeBSD 8.0, many LSI cards use the mpt driver, for which there is now an mptutil to monitor and manage RAID arrays. I will have an associated Nagios plugin very soon!


FreeBSD has great support for LSI MegaRAID adapters, until you try to monitor them, or get their status. LSI has opted to keep all their drivers and software proprietary. There is a Linux binary to get the functionality we need. In order to use it, we've got to do a couple things to our system.

Hardware Setup

For our setup, we're using a Dell PowerEdge R300 server with a Dell PERC 6/E, connected to a Dell PowerVault MD1000 via SAS.

Linux Compat

To get megacli installed, we need to enable linux binary compatibility. In addition, we need to enable Fedora Core 6, which is in dev. To do this, please do the following: <ol><li>Add 'compat.linux.osrelease=2.6.12' to /etc/sysctl.conf</li> <li>Install /usr/ports/emulators/linux_base-fc6</li> <li>Add the following two lines to /etc/fstab: <pre>linproc /compat/linux/proc linprocfs rw 0 0 linsysfs /compat/linux/sys linsysfs rw 0 0</pre></li> </ol>

megacli

<ol><li>In our setup, the only RAID adapter we had showed up as host1, rather than host0, in the linux proc device. To fix this, we need to edit some system source. Edit /usr/src/sys/compat/linsysfs/linsysfs.c, and change line 180: <br /><br /> Original: <pre>if (dinfo->cfg.baseclass == PCIC_STORAGE) {</pre> New: <pre>if (dinfo->cfg.baseclass == PCIC_STORAGE && dinfo->cfg.subclass == PCIS_STORAGE_RAID) {</pre> </li> <li>Now, cd /usr/src and make buildkernel && make installkernel. Don't reboot quite yet.</li>

<li>As of 11/5/2008, the FreeBSD port for linux-megacli was listed as broken due to an unfetchable file. I don't know the backstory to this, but I've found the file and you can download it here. Place this file in /usr/ports/distfiles.</li>

<li>Install the /usr/ports/sysutils/linux-megacli port. Feel free to ignore the install notes that come up, as they're all covered here.</li> <li>Add the following line to /boot/loader.conf: <pre>mfi_linux_load="YES"</pre></li> <li>Reboot.</li> </ol>

Testing

After you've rebooted your system, you should be able to run the following command and get output describing your disk layout: <pre># megacli -LDInfo -LALL -aALL</pre>

Here's our output from the above command with a 12 disk RAID 50: <pre>Adapter 0 -- Virtual Drive Information: Virtual Disk: 0 (Target Id: 0) Name: RAID Level: Primary-5, Secondary-3, RAID Level Qualifier-3 Size:4764160MB State: Optimal Stripe Size: 64kB Number Of Drives:6 Span Depth:2 Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU Access Policy: Read/Write Disk Cache Policy: Disk's Default</pre>

Nagios Monitoring

The following script, coupled with Nagios and NRPE will allow you to monitor the status of your MegaRAID adapter: <pre>#!/usr/bin/perl -w use strict; use warnings;

use lib "/usr/local/libexec/nagios"; use utils qw(%ERRORS);

my $usage = "Usage: check_mega_raid\nEvaluates whether volume is in optimal state\n"; my $output = ""; my $errs = 0; my $index = 0; my $count = 0; my (@disk_status_fmt); my (@part, $enclosure_id, $slot_number, $state, $progress_hosts);

my $status = `/usr/local/sbin/megacli -ldinfo -L0 -aall| /usr/bin/grep State`; if ($status =~ m/^State: (.*)$/){ $output .= "RAID Volume $1. "; if ($1 =~ m/Optimal/){ } elsif ($1 =~ m/Degraded/) { ## Pull data from all disks. Grab current enclosure ID and slot number. my @disk_status = `/usr/local/sbin/megacli -ldpdinfo -aall`; while (my $line = shift @disk_status){ if ($line =~ m/^\w/){ push @disk_status_fmt, $line; } } splice @disk_status_fmt, 0, 16; while (@disk_status_fmt){ @part = splice @disk_status_fmt, 0, 16; while (my $line = shift @part){ if ($line =~ m/Slot Number: (\d+)$/){ $slot_number = $1; } elsif ($line =~ m/Enclosure Device ID: (\d+)$/){ $enclosure_id = $1; } elsif ($line =~ m/Firmware\sstate:\s(\w+)$/){ $state = $1; } } if ($state =~ m/Online/){ } elsif ($state =~ m/Rebuild/){ $errs++; my $rebuild_status = `/usr/local/sbin/megacli -pdrbld -showprog physdrv\[$enclosure_id:$slot_number\] -a0 | /usr/bin/grep Reb`; if ($rebuild_status =~ m/^.*Completed (\d+)%/){ $output = $output . "$enclosure_id:$slot_number $state ($1%);"; } } else { $errs++; $output = $output . "$enclosure_id:$slot_number $state; "; } } ## We have a drive rebuilding, let's get it's progress. # megacli -pdrbld -showprog physdrv\[12:0\] -a0 # Rebuild Progress on Device at Enclosure 12, Slot 0 Completed 1% in 2 Minutes.

} } print "$output\n"; if ($errs gt 0){ exit $ERRORS{'CRITICAL'}; } else { exit $ERRORS{'OK'}; }</pre>